CALCULATOR
Voltage divider
Compare the unloaded output with the voltage under a load resistance R_L. The result is calculated locally and instantly.
The load is connected across R2. Enter its resistance to compare the loaded and unloaded output.
How to use this calculator
Compare the ideal unloaded output with the output when a resistive load is connected across R2. Leave R_L blank for no load.
Formula and units
Unloaded: Vout = Vin × R2 ÷ (R1 + R2). Loaded: replace R2 with R2 ∥ R_L = (R2 × R_L) ÷ (R2 + R_L), then use Vout = Vin × (R2 ∥ R_L) ÷ (R1 + (R2 ∥ R_L)).
Worked example
With Vin = 12 V and R1 = R2 = R_L = 1 kΩ, the unloaded output is 6 V. The load makes the lower leg 500 Ω, so the loaded output is 12 × 500 ÷ 1,500 = 4 V.
Common mistakes and limitations
The calculation assumes ideal, fixed resistors and a resistive load. Real input circuits can draw pulsed or nonlinear current; resistor tolerance, source resistance, temperature and power rating also affect results. A divider is usually a poor power supply; buffer it or choose a suitable regulator when the load needs a stable voltage.