To measure ripple on a 5 V supply, observe the small AC component riding on the DC output, directly across the output terminals or output capacitor, using a probe with a very short ground loop. A long ground clip can pick up the converter’s magnetic field and create spikes that are not present at the output. Record the load, test point, coupling and bandwidth limit with every reading. This procedure is for an isolated low-voltage supply; it never makes it safe to connect an oscilloscope ground to a non-isolated mains circuit.

What the measurement represents

Ripple is residual periodic or quasi-periodic variation around the DC level. A switching converter can contribute its switching frequency and harmonics, along with transients caused by load changes. Probe pickup, the ground connection, bandwidth setting and measurement algorithm also affect the display. The reading is therefore not independent of the method: compare it with the supply manufacturer’s stated test conditions or the product’s own validation procedure.

“5 V” does not mean the output is exactly 5.000 V, and not every variation is ripple. First check the DC component with a multimeter and inspect the waveform on the scope. Slow voltage drift, sag under a heavier load or regulator restart calls for a regulation or transient test, not just a ripple reading.

Oscilloscope probe connected across a low-voltage output capacitor with a short ground spring
Original illustration: a short connection reduces the probe loop area.

Set up a repeatable comparison

  1. Read the limits before connecting. Identify whether the output return is bonded to protective earth, whether the output is isolated, and where circuit 0 V is. A bench oscilloscope ground clip is generally tied to protective earth. Never attach it to a floating or mains-referenced node without a suitable differential probe and procedure.
  2. Define a load. Measure unloaded only when that answers the question. To characterize the supply, choose a load representative of use, check its current rating, and use a properly rated electronic load or power resistor. Example: a 10 Ω resistor at 5 V would dissipate 2.5 W in theory, so the resistor needs suitable thermal margin. This is an example calculation, not a measurement.
  3. Choose a repeatable point. Place the probe tip close to the output terminals or capacitor and the ground spring on the adjacent return. Avoid a long cable when measuring the converter output itself; it adds inductance and pickup.
  4. Compensate and verify the probe. Use a known probe factor, often 10× to reduce loading, and compensate it as the instrument manual specifies. The channel’s 1×/10× setting must match the probe.

Set the oscilloscope in sequence

  1. Connect the channel with the short ground. Begin in DC coupling and choose a vertical range that shows the output without clipping.
  2. Stabilize the trigger, then use AC coupling or vertical offset to magnify the small variation. AC coupling removes the DC component at the channel input, but it can distort slow changes; do not use it alone to judge drift or a long transient.
  3. Choose a time base that shows several ripple periods. A very long time base can hide fast switching content, while a very short view can miss slow regulation changes.
  4. Apply the bandwidth limit required by the specification. A 20 MHz limit is common in published ripple methods, but it is not a universal rule. Keep a full-bandwidth capture too if higher-frequency noise matters.
  5. Use a peak-to-peak measurement only after checking the waveform and time scales. Record RMS too when needed; Vpp and Vrms are not interchangeable.
Oscilloscope showing a small ripple waveform after the DC level is removed
Original illustration: AC coupling magnifies ripple but does not replace a DC view.

Tell real ripple from a probe artifact

ObservationPossible causeUseful discriminator
Large spikes change when the ground lead movesProbe loop picking up the converter fieldReplace the long clip with a ground spring; keep test point and load unchanged
Stable periodic waveform at the outputConverter ripple or real coupling at the measured nodeCompare with expected frequency, check a second local point and use specified bandwidth
Slow dip during a load changeTransient response, wiring drop or current limitTrigger on the load step and view milliseconds before and after
Different reading between capturesDifferent load, scale, acquisition or bandwidthRepeat with written settings and save the scope setup

If a long ground lead shows ringing that disappears with the spring, a measurement contribution is likely. If the waveform remains similar with a short connection at the same point, investigate it further, but it does not prove a failed capacitor by itself. Compare the result with the applicable limit, frequency, load and operating temperature.

Visual comparison between a long oscilloscope ground lead and a short ground connection
Original illustration: the probe ground path can add apparent ringing.

Record a result another person can reproduce

Write down the supply model, DC output, load and load current, exact test point, probe and attenuation, ground length, coupling, bandwidth, time base, vertical range and measurement type (mV peak-to-peak or RMS). Save a screenshot. A comparison such as “12 mVpp versus 8 mVpp” is meaningful only when both captures use comparable conditions.

Should AC coupling always be used?

No. It helps enlarge millivolt ripple on a 5 V rail, but a DC view shows the actual level, excursions and slow events. Use both when overall behavior matters.

Why does a 20 MHz limit change the reading?

It filters faster components and often reduces pickup. That may be needed for comparison with a specification, but a full-bandwidth capture answers a different question. State the limit used.

Should the ground clip go to chassis?

For a low-voltage output measurement, probe return belongs on circuit 0 V at the test point. Chassis is suitable only if it is the same electrical node and the grounding is understood. See also how to avoid a short with an oscilloscope ground clip and how to compensate a 10× probe.

Technical sources

Sources consulted November 2, 2026. Acceptable ripple depends on the model, its data sheet and the measurement conditions.